4. Maintenance

No maintenance is required, as long as the unit is used as intended within the specified condi-
tions.

5. Installation

5.1 Mounting / Removal

Before mounting or removing the unit:

Prevent damage to internal electronics from electrostatic
discharges (ESD) by discharging your body to a grounding
point (e.g. use of wrist strap).

Prevent access to hazardous voltages by disconnecting the
unit from AC/DC mains supply and all other electrical
connections.

Mounting

This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or
cabinet backplate.
This unit uses convection cooling.To avoid obstructing the airflow around the unit,
use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10
mm (0.4 inches) left/right the unit.
Snap on mounting, see figure

Removal

Press down the black support at the back of the unit using
a screwdriver, see figure.

10 mm *

(0.4 inches)

CLICK!

!

25 mm

25 mm

* Spacing (left/right) recommend-

ed for full operating temperature
range