Westermo TD-34 User Manual

Page 46

Advertising
background image

46

6610-2203

S6 – Wait Time before Blind Dialing or for Dial Tone
Sets the length of time, in seconds, that the modem will wait for dial tone when encountering
a “W” dial modifier before returning NO DIAL TONE result code.
The modem always pauses for a minimum of 2 seconds, even if the value of S6 is less than 2
seconds.
Range: 2–60 seconds
Default: 4

S7 – Wait Time for Carrier, Silence, or Dial Tone
S7operation is country dependent.
1. Sets the length of time, in seconds, that the modem will wait for carrier before hanging up.

The timer is started when the modem finishes dialing (originate), or 2 seconds after going
off-hook (answer). In originate mode, the timer is reset upon detection of answer tone if
allowed by country restrictions.

2. Sets the length of time, in seconds, that modem will wait for silence when encountering the

@ dial modifier before continuing with the next dial string parameter.

Range: 1–255 seconds
Default: 50

S8 – Pause Time For Dial Delay
S8 sets the time, in seconds, that the modem must pause when the “,” dial modifier is encoun-
tered in the dial string.
Range: 0–255 seconds
Default: 2

S9 – Carrier Detect Response Time
S9 is supported for backwards compatibility only. No value can be written. Responds with
default value.
Range: 6 tenths of a second
Default: 6 (0.6 second)

S10 – Lost Carrier To Hang Up Delay
S10 sets the length of time, in tenths of a second, that the modem waits before hanging up
after a loss of carrier.This allows for a temporary carrier loss without causing the local
modem to disconnect.When register S10 is set to 255, the modem functions as if a carrier is
always present.The actual interval the modem waits before disconnecting is the value in regis-
ter S10 minus the value in register S9.
Therefore, the S10 value must be greater than the S9 value or else the modem disconnects
before it recognizes the carrier.
Range: 1–255 tenths of a second
Default: 14 (1.4 seconds)

S11 – DTMF Tone Duration
S11 operation is country dependent.
Range: 50–255 milliseconds
Default: 95 (95 milliseconds)