Westermo TD-34 User Manual

Page 39

Advertising
background image

39

6610-2203

*WIOD – General IO delete entry

This command delete an IO entry in the list.

Syntax:

AT*WIOD=<index>[,<start,stop>]
AT*WIOD=?
<index>

IO entry index

[,<start,stop>] IO entry start,stop index

Examples:

AT*WIOD=2
OK
AT*WIOD=3,7

OK
AT*WIOD=?
*WIO: (1-8)[,(1-8)]
OK

Result Codes:

OK

<index>[,<start,stop>] = (1-8)[ (1-8,1-8)]

ERROR

Otherwise

*WIOP – General IO parameters

This command set the IO parameters.

Syntax:

AT*WIOP=<t0>,<t1>,<type>,<trig>,<norm>
AT*WIOP=?
AT*WIOP?
<t0>

Min trig pulse time in 10 ms [0-255]

<t1>

Max trig pulse time in 10 ms [0-255]

<type>

Trig pulse type [0=NO, 1=LEVEL, 2=PULSE]

<trig>

Pulse trig type [0=NO, 1=HIGH, 2=LOW, 3=POS, 4=NEG]

<norm>

Normaly [0=NO, 1=OPEN, 2=SHORT, 3=DCD, 4=DTR]

Examples:

AT*WIOP=5,10,1,1,3
OK
AT*WIOP=,,2,,
OK
AT*WIOP?
*WIO :TMIN=5,TMAX= 10,TYPE=2,TRIG=1, NORM=3
OK

Result Codes: OK

<t0>,<t1>,<type>,<trig>,<norm> = (0-255), (1-255), (0-2),
(0-4), (0-4)

ERROR

Otherwise:

*WRAE – End remote access

This command end the remote access session.

Syntax:

AT*WRAE

Examples:
Result Codes:
OK

Advertising
This manual is related to the following products: