Westermo TD-34 User Manual

Page 49

Advertising
background image

49

6610-2203

S25 – Delay To DTR
S25 sets the length of time that the modem will ignore DTR for taking the action specified by
&Dn. Its units are one hundredths of a second for other modes.
Range: 0–255 (0.01 seconds)
Default: 5 (0.05 seconds)

S29 – Flash Dial Modifier Time
S29 sets the length of time, in units of 10 ms, that the modem will go on-hook when it
encounters the flash (!) dial modifier in the dial string.The time can be limited as it is a coun-
try dependent parameter.
Range: 0–255 10 ms intervals
Default: 0 (0 ms)

S30 – Disconnect Inactivity Timer
S30 sets the length of time, in tens of seconds, that the modem will stay online before discon-
necting when no data is sent or received. In error-correction mode, any data transmitted or
received will reset the timer. In other modes, any data transmitted will reset the timer.
Range: 0–255 tens of seconds (0–2 550 seconds)
Default: 0 (disabled)

S31 – Bit Mapped Options Status
S31 indicates bit mapped options status.
Bit 0 Single line connect message enable/disable (\Vn)

0 = Messages controlled by S95,Wn and Vn (\V0) (Default)
1 = Single line connect message (\V1)

Bit 1 Auto line speed detection (Nn)

0 = Disabled (N0)
1 = Enabled (N1) (Default)

Bits 2–3 Error correction progress messages (Wn)

0 = DTE speed only (W0)
1 = Full reporting (W1) (Default)
2 = DCE (line) speed only (W2)

Bits 4–5 Not used

0 = (Default)

Bits 6–7 Reserved (Default = 11b)

Advertising
This manual is related to the following products: