Step 3: prepare for waterproof installation – ACTi KCM-7111 User Manual

Page 13

Advertising
background image

www.acti.com

Hardware Manual

13

Step 3: Prepare for Waterproof Installation

The camera comes with two (2) glands used for waterproof installation:

Cable Gland

: For use with an

Exterior-grade Ethernet cable

. Exterior-grade Ethernet

cables are already waterproof. See

Waterproof Solution with Naked Cable

on page 14.

Conduit Gland

: For use with a flexible conduit. This solution is recommended when an

exterior-grade Ethernet cable is not available or when other input/output devices or

external power adapter will be connected to the camera. See

Waterproof Solution with

Conduit

on page

16.

Determine the type of waterproof solution that is applicable to your installation requirements and

prepare the necessary accessories or purchase extra materials.

Cable Gland

Conduit Gland

For use with an

Exterior-grade Ethernet

cable

(not included in the package).

For use with a

3/8”

flexible conduit (not

included in the package).

For use with

1/2”

flexible conduit (not included

in the package)

NOTE:

The bundled conduit gland may vary.

Check the conduit gland that came with your
package to determine if 3/8” or 1/2" is the
suitable flexible conduit size.

or