Table 1-1. Product Matrix

OXT4C

OXYMITTER 4000 - EXPLOSION PROOF - IN SITU OXYGEN TRANSMITTER

Explosion Proof Oxygen Transmitter - Instruction Book

Code

Sensing Probe Type with Flame Arrestor

1

Ceramic Diffusion Element Probe (ANSI 3 in. 150 lbs)

2

Snubber Diffusion Element (ANSI 3 in. 150 lbs)

3

Ceramic Diffusion Element Probe (DIN 2527) - 1/4 in. Tube Fittings

4

Snubber Diffusion Element (DIN 2527) - 1/4 in. Tube Fittings

5

Ceramic Diffusion Element Probe (JIS)

6

Snubber Diffusion Element (JIS)

7

Ceramic Diffusion Element (ANSI 3 in. 300 lbs)

8

Ceramic Diffusion Element (ANSI 4 in. 300 lbs)

Code

Probe Assembly

0

18 in. (457 mm) Probe

1

18 in. (457 mm) Probe with 3 ft (0.91 m) Bypass

2

18 in. (457 mm) Probe with Abrasive Shield

(1)

3

3 ft (0.91 m) Probe

4

3 ft (0.91 m) Probe with Abrasive Shield

(1)

5

6 ft (1.83 m) Probe

6

6 ft (1.83 m) Probe with Abrasive Shield

(1)

Code

Mounting Adapter - Stack Side

0

No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)

1

New Installation - Square weld plate with studs

2

Model 218 Mounting Plate (with Model 218 Shield Removed)

3

Competitor’s Mount

(2)

Code

Mounting Adapter - Probe Side

0

No Adapter Plate

1

Probe Only (ANSI)

2

New Bypass or New Abrasive Shield (ANSI)

4

Probe Only (DIN)

5

New Bypass or New Abrasive Shield (DIN)

7

Probe Only (JIS)

8

New Bypass or New Abrasive Shield (JIS)

Code

Electronic Housing and Filtered Customer Termination - NEMA 4X, IP66

11

HART

®

Integral Electronics, Standard Filtered Termination,

ATEX Certification

12

HART

®

Integral Electronics, Transient Protected Filtered Termination,

ATEX Certification

13

HART

®

Remote Electronics (requires cable), Standard Filtered Termination,

ATEX Certification

14

HART

®

Remote Electronics (requires cable), Transient Protected Termination,

ATEX Certification

21

HART

®

Integral Electronics, Standard Filtered Termination,

CSA/FM Certification

22

HART

®

Integral Electronics, Transient Protected Termination,

CSA/FM Certification

23

HART

®

Remote Electronics (requires cable), Standard Filtered Termination,

CSA/FM Certification

24

HART

®

Remote Electronics (requires cable), Transient Protected Termination,

CSA/FM Certification

OXT4C