General -1, Hazardous area oxymitter 4000, Instruction manual – Emerson Process Management OXYMITTER 4000 User Manual

Page 69

Advertising
background image

Instruction Manual

IB-106-340C Rev. 4.1

July 2004

Rosemount Analytical Inc. A Division of Emerson Process Management

Configuration with LOI 4-1

Hazardous Area Oxymitter 4000

SECTION 4

CONFIGURATION OF HAZARDOUS AREA

OXYMITTER 4000 WITH LOI

Install all protective equipment covers
and safety ground leads before
equipment startup. Failure to install
covers and ground leads could result
in serious injury or death.

4-1 GENERAL

a. Verify Mechanical Installation

Ensure the Hazardous Area Oxymitter 4000

is installed correctly. See Section 2,
INSTALLATION.

Opening the electronics housing in
hazardous areas may cause an explo-
sion causing severe injury, or death.
It may be required to get a hot work
permit from your company safety offi-
cer before you open the housing.

b. Verify Terminal Block Wiring

1. Remove screw (18, Figure 9-3 or

Figure 9-4), cover lock (19), and cap-
tive washer (20) that secure cover (17)
on left side of housing (11). Remove
the cover to expose the terminal block
(15).

2. Check the terminal block wiring

(Figure 3-1). Be sure the power, the
4-20 mA signal, and the logic outputs
are properly connected and secure.
To avoid a shock hazard, the power
terminal cover must be installed.

For units with remote electronics,
check the terminal block wiring at the
probe and at the remote electronics
unit.

3. Install the cover (17, Figure 9-3 or

Figure 9-4) over terminal block (15)
and secure with captive washer (20),
cover lock (19), and screw (18).

A

C

L1

A

C

N

+

+

-

-

4-20

500 VA

SERIAL NO.
TAG NO.

OXYMITTER 4000

WATTS:

VOLTS:

FUSE:

LINE

OUTPUT:

Rosemount Analytical Inc.
Orrville, OH 44667-0901

85-264 VAC 48-62 Hz

TM

800-433-6076

4-20 mA

R

5 Amps

TM

HART

SMART FAMILY

4-20 mA
SIGNAL

LOGIC I/O

GROUND LUGS

TERMINAL
BLOCK

HAZARDOUS AREA
OXYMITTER 4000
ELECTRONICS
HOUSING

37270010

LOI

Figure 4-1. Electronics Housing Terminals with LOI