Northfire 3400, 26 servicing – Archgard 3400-DVTR20N-2 User Manual

Page 26

Advertising
background image

Northfire 3400

26

SERVICING

Cont...

Open the lower grills.

The pressure test taps are located on the valve.

Automatic valve: The taps are located in the front. The inlet is marked ‘IN’ and the outlet is

marked ‘OUT’. There is also an arrow marking the direction of gas flow.

Manual valve: The taps are located on the left side of the valve. The connection closest to

the back, marked with ‘IN’ is the inlet and the outlet marked with ‘OUT’ is
closest to the front.

Loosen the set screw inside the tap with a 1/8” wide flat screw driver.

Connect a 1/4” rubber tube to the tap and to the manometer.

Be sure to tighten the set screw inside the tap after you are finish taking pressure readings.

Check for leaks.

CHECKING INLET AND OUTLET GAS PRESSURE

CHECKING AND ADJUSTING PILOT

The

pilot flame should have the characteristic as shown in the illustration below. The flame

should not have yellow tips but should engulf the thermocouple and thermopile. It can be adjusted
be turning the screw marked “pilot” on the control valve.

CHANGING MAIN BURNER ORIFICE

Remove the glass door, log set and brick panels (if used)

Remove the burner by removing the screws holding the burner and cover plate

Use two wrenches to loosen and remove the cap orifice.

Change the orifice.

Replace the burner and the log set and brick panels if used.

Test fire the appliance with the glass door off and check for gas leaks.

Replace the glass door.