IF YOUR GLASS BREAKS

CONVERTIBLE PILOT ORIFICE

In the event your glass cracks or breaks, it must be replaced by the exact same size and mate-
rial. It is made from high temperature ceramic material. See replacement parts list and contact
your nearest Archgard dealer.

Remove door and carefully remove all traces of glass and gasket material. See page 16 for
glass door removal.

Clean glass fame & ensure no “old” gasket or glue remains.

Install new glass and gasket. The “thicker” side of the gasket fits against the fireplace

opening.

Hold glass in place by using the sealer between gasket and door. Use sparingly so that no
excess will be visible. DO NOT PUT ANY SEALER BETWEEN GLASS AND UNIT
OPENING.

Replace the door carefully making sure all clamps are closed.

The pilot assembly is convertible to the type

of gas being used; simply unscrew the body
by using a 7/16” (11 mm) wrench turn a ¼
open then push the small metal tab across to
the other side of the body and retighten. Call
your local Authorized Archgard Dealer to
purchase the correct fuel conversion kit
for your gas appliance.