Northfire 3400

5

GENERAL INFORMATION

This appliance is listed by LabTest Certification for use in both the United States and Canada. It
is tested and certified to the following US and Canadian gas appliance standards.

- ANSI Z21.88b-2002 / CSA 2.33b-2002, Vented Gas Fireplace Heaters and
- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes.

Please contact Archgard Industries Ltd., if you have any questions regarding the certification of
this appliance.

APPLIANCE CERTIFICATION

INSTALLATION CODES

This appliance must be installed by a qualified gas appliance installer.
The installation must conform with the local codes or, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1 or the current CAN?CGA B149, Installation
Codes.

The appliance, when installed, must be electrically grounded in accordance with local codes or,
in absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.

We recommend that our gas hearth products be installed and serviced by professionals who are
certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.

HIGH ALTITUDE INSTALLATION

When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be
properly de-rated and installed according to local codes; in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
CAN/CGA-B149, in Canada.

SPECIFICATIONS

Natural Gas (NG)

Propane (LP)

Manifold Pressure

1.6 - 3.5 in. w.c. (0.4 - 0.9 kPa)

6.3 - 10.0 in. w.c. (1.5 - 2.5 kPa)

Minimum Supply Pressure for
Purpose of Input Adjustment

4.5 in. w.c. (1.2 kPa)

11.0 in. w.c. (2.8 kPa)

Orifice Size

#45 DMS ( 2.18 mm dia.)

#55 DMS ( 1.32 mm dia.)

Nominal Input Rating

13,000 - 20,000 BTU/hr (3.8 -5.8 kW) 15,000 -20,000 BTU/hr (4.4 - 5.8 kW)

Altitude

0 - 4,500 ft. (0 - 1372 m)

0 - 4,500 ft. (0 - 1372 m)

Primary Air Opening

¼ in. (6 mm)

Full open