Northfire 3400

8

CLEARANCES TO COMBUSTIBLES

Combustible mantle allowed in shaded area.
Mantle extension may be increased 1” (25mm)
for each additional 1” (25mm) increase in
clearance height.

6” (152 mm

)

Minimum Height From Top Surround: 6”

Minimum Height From

Bottom of Appliance: 35”

BACK

0” to stand-offs

SIDES

0” to stand-offs

TOP

0” to stand-offs

BOTTOM

0”

ADJACENT SIDE WALL

1” to side of faceplate

MANTLE

see diagram

VENT

1” to outside side and bottom surface
2” to outside top surface.

CLEARANCE TO COMBUSTIBLES

PRECAUTIONS

This appliance must be installed by a qualified gas installer and the installation must conform to the
installation codes.

Provide adequate clearance around air openings of the appliance. Never obstruct front openings.

Provide adequate clearances for proper operation and servicing of the appliance.

This appliance must be properly connected to a venting system.

NOTE: Low profile wooden crowns and moldings above the unit are not considered as mantles. I.E. 1” or less
protrusions on the upper mantle facing are acceptable

6” (152 mm)