background image

Figure 12 Recover IRF member switches (approach II)

Follow these steps to manually recover an IRF fabric in recovery state:

To do…

Use the command…

Remarks

Enter system view

system-view

Recover an IRF fabric in recovery
state

mad restore

Required

NOTE:

For a switch that transitioned to recovery state due to the multi-active collision, if you need to bring up one
of its port that are already shut down, H3C recommends that you execute the mad restore command to
recover the switch and make it operate in the active state instead of executing the undo shutdown

command to perform a manual recovery.

IRF configuration fast recovery

If a member switch has only one MPU and that board is corrupted, use the following fast recover function

to avoid complicated IRF configuration.

Configuration prerequisites

H3C recommends that you perform the fast recovery operation when the switch operates in IRF
mode.