1-24
Table 1-31
Status LEDs for LPU modules
LED
Status
ON
The module is faulty.
OFF
The module is faulty or out of position.
Blinking (1s)
The module is running normally.
RUN
Fast blinking
(125ms)
The module is booting or not registered
successfully.
ON
The module has alarms.
ALM
OFF
The module has no alarms or is out of position.
2~6
Indicate slots 2 through 6
z
Status LEDs for the SRP1N6 module
You can learn the operating status of SRP1N6 module by reading the SFS, ACT, ALM
and RUN LEDs on it. The following table gives a summary of the four LEDs.
Table 1-32
Status LEDs for the SRP1N6 module
SRP1N6 LED
Status
ON
The switching fabric unit is active.
SFS
OFF
The switching fabric unit is standby.
Green
The SRP1N6 module is faulty.
OFF
The SRP1N6 module is faulty.
RUN
Green blinking
The SRP1N6 module runs normally.
Red
The SRP1N6 module has alarms.
ALM
OFF
The SRP1N6 module has no alarms.
Green
The SRP1N6 module is active.
ACT
OFF
The SRP1N6 module is standby.
IV. SRP1N7 module
1) Specifications
The S9512, 9508 and 9505 can use SRP1N7 modules, which integrate clock modules