Cooling system failure, Interface module, cable, and connection failure – H3C Technologies H3C SR6600 User Manual

Page 63

Advertising
background image

55

|<7> BootWare Operation Menu |

|<8> Clear Super Password |

|<9> Storage Device Operation |

|<0> Reboot |

======================================================================

Enter your choice(0-9):8

The following output indicates that you have successfully cleared the super password.

Clear Application Password Success!

NOTE:
•

Select option 8, quit the menu, reboot the router, and then you can enter system view directly.

•

This setting (password clearing) is valid only for the first reboot of the router. The super password will be
restored after a second reboot.

Cooling system failure

When the temperature inside the router exceeds 45°C (113°F), the cooling system may have failed.
Follow these steps to troubleshoot the cooling system:

Step1

Check whether the fans are running properly.

Step2

Check whether the working environment of the router is well ventilated.

Step3

If the temperature inside the router exceeds 75°C (167°F), the following information appears on the
configuration terminal:

%Jun 28 10:27:27:653 2010 H3C DRVMSG/3/Temp2High:

Environment temperature too high in Slot 0, index is 1.

#Jun 28 10:27:28:432 2010 H3C DEV/1/BOARD TEMPERATURE UPPER:

Trap 1.3.6.1.4.1.2011.2.23.1.12.1.16<hwBoaardTemperatureHigher>:frameIndex is

0, slotIndex 0.0

%Jun 28 10:27:28:433 2010 H3C DEV/4/BOARD TEMP TOOHIGH:

Board temperature is too high on Frame 0 Slot 0, type is RPU.

Step4

Use the display environment command to check whether the temperature in the router keeps rising. If the
temperature inside the router exceeds 90°C (194°F), power off the router immediately and contact your

local sales agent.

NOTE:

For more information about the display environment command, see the

H3C SR6600 Routers

Fundamentals Command Reference.

Interface module, cable, and connection failure

After an HIM/MIM is installed and the router is powered on, the LEDs on the HIM/MIM panel indicate
abnormal operation.
Follow these steps to solve this problem:

Advertising