2000net module alarm dip switches – Grass Valley 2000NET v4.0.0 User Manual

Page 21

Advertising
background image

2000NET Instruction Manual

21

Status Monitoring and Reporting

continuous voltage level to the Module Health bus indicating that a
problem exists on the module but will not indicate what the problem is.
Alarms and SNMP Monitoring

Faults and alarms from the 2000NET module can be reported to a Frame
Health Alarm connector on the rear of the 2000T3 frame (see

Frame Health

Alarm Connection on page 12

) and/or to a networked SNMP monitoring

system (see

SNMP Monitoring on page 24

).

2000NET Module Alarm DIP Switches

Two eight-position DIP switches (S1 and S2) enable or disable the overall
fault and alarm reporting functions of the module. The current status of
these settings is reported on the Status web page of the 2000NET GUI
(

page 45

), the Frame Alarm Reporting web page (

page 36

), and the SNMP

Reporting web page (

page 38

). Disabling (or filtering) of fault reports can

also be useful in isolating problems in the frame.

The Frame Health Alarm on the rear of the Kameleon 2000 Series frame
responds directly to the settings of the DIP switches. Some media modules
provide enabling/disabling of Frame Health reporting for Slot Status,
Signal Loss and Reference Loss on the Slot Config web page for the media
module. Refer to

Media Module Slot Configuration on page 51

for details.

Refer to

Figure 15

for the location of S1 and S2 and

Table 3 on page 22

for

the possible settings. A settings table is also silk-screened on the bottom of
the module.

Figure 15. DIP Switches S1 and S2

12345678

12345678

S2

S1

Power Supply #3
Power Supply #4

Power Supply #1
Power Supply #2

Fan

Module

Frame Bus

NM Control

Asynchronous Status

Frame Control

8046_48