Nearline system power-off procedure
“Administering and maintaining the K2 Storage
.
Nearline system power-off procedure
Use the following sequence to power-off the Nearline storage system.
1. Stop all FTP streams or other media operations on the nearline storage system.
2. Shut down the K2 Media Servers.
3. Power-off the primary RAID controller chassis. If expansion chassis are
connected, make sure the power-off of the controller chassis is prior to or
simultaneous with the power-off of its connected expansion chassis. Wait
approximately 30 seconds for the disk drives to spin down before proceeding.
4. Power-off all Ethernet switches.
5. Power-off the control point PC and/or the NetCentral server PC, if necessary.