Panel Configuration

Router Interface Option Configuration

To use the Newton Router Interface, first enable the option for the rack
mount (

Enable Router Interface on Rack Mount Panel on page 42

) and/or soft

panel (

Enable Router Interface on NewtonPC on page 30

).

In Newton Panel Configurator, select the Router Configuration tab, then
select the type of router connection to be used as one of the following:

None

If not using the router interface, select

None

and all fields will be grayed out,

Native Protocol

Enter the following for a Native Protocol connection (

Figure 47

):

Primary Router IP Address

– enter the IP Address of the Primary MCPU in

this field.

Secondary Router IP Address

– enter the IP Address of the Secondary MCPU

in this field.

Monitored Destination

– enter the name of the destination to be monitored

by the Newton panels exactly as it appears on the router list.

Monitored Level

– enter the router level to monitor for the destination (a

number between 1-64).

Destination Lock

– selecting this checkbox locks the Monitored Destina-

tion from being changed from the panel.

Figure 47. Configure Router Interface – Native Protocol