Environmental criteria – Grass Valley PVS Series System Guide v.4.0 Dec 10 200 User Manual

Page 257

Advertising
background image

Environmental Criteria

July 27, 2001

Profile XP System Guide

257

Environmental Criteria

The following table lists the environmental criteria for the Profile XP Media Platform,
PFC500, and the PAC216.

Characteristics

Description

Operating Temperature

Requirement:

10

°

to 40

°

C

Storage Temperature

Requirement:

-40

°

to 65

°

C

Operating Altitude

Requirement:

To 10,000 feet

Supplemental Data:

IEC 950 compliant to 2000 meters

Storage Altitude

Requirement:

To 40,000 feet

Mechanical Shock

Supplemental Data: Class 5 (30G) Tektronix 062-2858-00 RevB

Random Vibration

Requirement:

Operational: Class 6 Tektronix 062-2858-00 RevB

Requirement:

Non-Operational: Class 5 Tektronix 062-2858-00
RevB

Transportation

Requirement:

Tektronix 062-9527-00

Equipment Type

Supplemental Data:

Information Technology

Equipment Class

Supplemental Data:

Class 1

Installation Category

Requirement:

Category II Local level mains, appliances, portable
equipment, etc.

Pollution Degree

Requirement:

Level 2 operating environment, indoor use only.

Relative Humidity

Requirement:

Operating 80% from +30

°

to +40

°

C

Non-Operating 90% from +30

°

to +60

°

C

Do not operate with visible moisture on the circuit
boards

Advertising
This manual is related to the following products: