7 a d ditional f unctions – HEIDENHAIN TNC 320 (340 55x-05) ISO programming User Manual
Page 226
Advertising

226
Programming: Q Parameters
8.7 A
d
ditional F
unctions
Example: Assign the value of the active scaling factor for the
Z axis to Q25
23
-
PLC value
24
-
Tool type TYPE
0 = milling cutter, 21 = touch probe
27
-
Corresponding row in the touch-probe table
32
-
Point angle
34
-
Lift off
Touch probe cycles, 990
1
-
Approach behavior:
0 = standard behavior
1 = effective radius, set-up clearance is zero
2
-
0 = probe monitoring off
1 = probe monitoring on
4
-
0 = stylus not deflected
1 = stylus deflected
Execution status, 992
10
-
Block scan active
1 = yes, 0 = no
11
-
Search phase
14
-
Number of the last FN14 error
16
-
Real execution active
1 = execution , 2 = simulation
Group name, ID no.
Number
Index
Meaning
N55 D18: SYSREAD Q25 = ID210 NR4 IDX3