5 ether n et int e rf ace – HEIDENHAIN TNC 320 (340 55x-05) ISO programming User Manual
Page 407

HEIDENHAIN TNC 320
407
15.5 Ether
n
et Int
e
rf
ace
SMB option
Options that concern the SMB file system type:
Options are given without space characters,
separated only by commas. Pay attention to
capitalization.
Options:
ip:
IP address of the Windows PC to which the
control is to be connected.
username:
User name with which the control
should log in.
workgroup:
Workgroup under which the control
should log in.
password:
Password with which the control is
to log on (up to 80 characters)
Further SMB options: Input of further options
for the Windows network
Automatic
connection
Automount (YES or NO): Here you specify
whether the network will be automatically
mounted when the control starts up. Devices
that are not automatically mounted can be
mounted anytime in the program management.
You do not need to indicate the protocol with the TNC 320.
It uses the communications protocol according to RFC
894.
Setting
Meaning