2 interfaces and functions, Interfaces and functions – SMA SB 3000TL User Manual

Page 15

Advertising
background image

Symbol

Explanation

The product is suitable for outdoor installation.

Certified safety
The product is VDE-tested and complies with the requirements of the Ger-
man Equipment and Product Safety Act.

RCM (Regulatory Compliance Mark)
The product complies with the requirements of the applicable Australian
standards.

4.2

Interfaces and Functions

The inverter can be equipped or retrofitted with the following interfaces and functions:

BLUETOOTH

Via BLUETOOTH, the inverter can communicate with various BLUETOOTH devices (for information
on supported SMA products, see www.SMA-Solar.com).

SMA Speedwire/Webconnect

The inverter is equipped with SMA Speedwire/Webconnect as standard. SMA Speedwire/
Webconnect is a type of communication based on the Ethernet standard. This enables inverter-
optimized 10/100 Mbit data transmission between Speedwire devices in PV systems and the
software Sunny Explorer. The Webconnect function enables direct data transmission between the
inverters of a small-scale system and the Internet portal Sunny Portal without any additional
communication device and for a maximum of four inverters per Sunny Portal system. In large-scale
PV power plants, data transmission to the Internet portal Sunny Portal is carried out via the
SMA Cluster Controller. You can access your Sunny Portal system from any computer with an
Internet connection.
SMA Speedwire/Webconnect enables, for PV systems operated in Italy, the connection to or
disconnection of the inverter from the utility grid and definition of the frequency limits to be used
with IEC61850-GOOSE messages.

RS485 interface

The inverter can communicate via cables with special SMA communication products via the RS485
interface (information on supported SMA products at www.SMA-Solar.com). The RS485 interface
can be retrofitted.

Grid Management Services

The inverter is equipped with service functions for grid management.
Depending on the requirements of the grid operator, you can activate and configure the functions
(e.g. active power limitation) via operating parameters.

4 Product Description

SMA Solar Technology AG

Operating Manual

15

SB30-50TL-21-BE-en-11

Advertising