Problem

Cause and corrective measure

The SMA String-Moni-
tor cannot be acces-
sed.

The overvoltage protection unit is possibly defective or may have been
destroyed by surge voltage.
Corrective measures:

• Check whether the communication connection has been interrupted

by the overvoltage protection.
If this is the case, the overvoltage protection unit is defective.
Possibly due to overvoltage, e.g. a lightning strike. Perform the
following steps:

– Replace the overvoltage protection unit (see Section 5, page 28

).

– Check the assembly for visible damage, e.g., charred parts or

connections. If the assembly is damaged, contact the Service
(see Section 8, page 31).

– Check the Ethernet cable for visible damage, e.g., charred

areas on the cable sheath. If Ethernet cables are damaged,
replace them (see Section 5, page 28).

Ethernet connection is not set up correctly.
Corrective measures:

• On the user interface of the inverter, check the network connection

to the SMA String-Monitor (see inverter manual).

• Ensure that all Ethernet cable plugs are inserted and locked.
• Ensure that the system router/network switch is switched on.
• Ensure that all DC subdistributions in the communication bus are

fully operational.