9 operation, 1 display messages, 1 measuring channels – SMA SB 1300TL User Manual

Page 43: 2 status messages, Operation, Display messages, Measuring channels, Status messages, 9operation

Advertising
background image

9

Operation

9.1

Display Messages

9.1.1

Measuring Channels

Measuring channels are measured values shown on the display. Additionally, you can read out
further measuring channels via a communication product.

Measuring channel

Explanation

E-Today

Total amount of energy fed in

Status

Indicates the current operating state (see Section 9.1.2 "Status Mes-
sages", page 43)
.

Pac

AC power supplied

Vpv

PV input voltage

E-Total

Total amount of energy fed in

h-Total

Total number of operating hours in feed-in operation

Warning / Disturbance / Er-
ror

Display of a current disturbance or error with corresponding error
message (for troubleshooting, see service manual at www.SMA-So-
lar.com
). When certain disturbances occur, the disconnection value
and the current value are also displayed.

9.1.2

Status Messages

Status messages are shown in the second line of the display and always start with the word
"Mode". Status messages indicate operating states which do not represent errors or disturbances.
The inverter continues feeding into the utility grid.

Message

Explanation

Derating

This message can have several causes:

• Overtemperature in the inverter. The inverter reduces its power to prevent

overheating.

• External active power limitation via the Power Reducer Box and

Sunny WebBox. The inverter reduces its power output automatically due
to the grid operator's specifications. The Power Reducer Box transfers the
signal from the grid operator to the inverter via the Sunny WebBox.

Error

The inverter has detected an error. The specific error message is also dis-
played (for troubleshooting, see service manual at www.SMA-Solar.com).

MPP

The inverter is operating in MPP mode. MPP is the standard display message
when operating under normal irradiation conditions.

MPP-Peak

The inverter is operating in MPP mode above its nominal power.

MPP-Search

The inverter is calculating the MPP.

9 Operation

SMA Solar Technology AG

Operating Manual

43

SB13-21TL-BE-en-11

Advertising
This manual is related to the following products: