SMA SB 1300TL User Manual

Page 50

Advertising
background image

Power loss in night mode

0.1 W

Topology

transformerless

Cooling method

Convection

Degree of protection in accordance with
IEC 60529

IP65

Protection class in accordance with IEC 62103

I

Grid configurations

TN-C, TN-S, TN-CS, TT (if V

N_PE

 > 30 V), IT, Delta

IT, split phase

National standards and approvals, as per
10/2014*

AS 4777, C10/11, CE, CEI 0-21,

EN 50438:2007, G83/2, IEC 60068-2,

IEC 61727, IEC 62109-1, IEC 62109-2,

NRS 097-2-1, PPC, PPDS, RD1699,

RD 661/2007, UTE C15-712-1, VDE-AR-

N 4105, VDE0126-1-1, VFR 2014

* RD1699: Contact the SMA Service Line for restrictions in specific regions.

NRS 097-2-1: This standard requires a separate label attached to the AC distribution board which
indicates the AC-side disconnection of the inverter in case of a grid failure (for further details, see
NRS 097-2-1, Sect. 4.2.7.1 and 4.2.7.2)
IEC 62109-2: In order to meet the requirements of this standard, use of the fault indication relay must
be activated in the inverter or there must be a link to Sunny Portal with the fault alert via e-mail activated.

Protective Devices

DC reverse polarity protection

Short-circuit diode

Input-side disconnection point*

Electronic Solar Switch

DC overvoltage protection

Thermally monitored varistors

AC short-circuit current capability

Current control

Grid monitoring

SMA Grid Guard 2.1

Maximum permissible fuse protection

16 A

Ground fault monitoring

Insulation monitoring: R

iso

 > 1 MΩ

All-pole sensitive residual-current monitoring unit

Available

* Optional

Climatic Conditions

Installation in accordance with IEC 60721-3-3, Class 4K4H

Extended temperature range

−25°C to +60°C

Extended humidity range

0% to 100%

Extended air pressure range

79.5 kPa to 106 kPa

11 Technical Data

SMA Solar Technology AG

Operating Manual

SB13-21TL-BE-en-11

50

Advertising