5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 37B 1000-Series Option PG-X3 Installation Manual

21

Terminal Functions

Table 5 Option Terminal Functions

Terminal

Block

Terminal

Function

Description

TB1

<1> A separate power supply is needed if the PG requires more than 200 mA to operate. Select a UL-listed class 2

power supply.

A+

A pulse signal input

• Inputs for the A channel, B channel, and Z pulses

from the PG

• Signal level matches RS-422

A–

A inverse pulse signal input

B+

B pulse signal input

B–

B inverse pulse signal input

Z+

Z pulse signal input

Z–

Z inverse pulse signal input

SD

NC pin (open)

Open connection port for use when cable shields
should not be grounded

FE

Ground

Used as the shield ground termination point.

TB2

IP

PG power supply

• Output voltage: 12.0 V

± 5% or 5.5 V ± 5%

• Max. output current: 200 mA

<1>

IG

PG power supply common

SG

Monitor signal common

• Output signal for monitoring A channel, B channel,

and Z pulses from the PG

• Signal level matches RS-422

a+

A pulse monitor signal

a–

A pulse inverse monitor signal

b+

B pulse monitor signal

b–

B pulse inverse monitor signal

z+

Z pulse monitor signal

z–

Z pulse inverse monitor signal