Explicit Message Communications Errors

When there is a problem with a request message sent from the master in explicit

communications, the drive will return one of the following error codes.

Note: Refer to the MEMOBUS/Modbus Data Table in the Technical Manual for a list of monitor data

using the MEMOBUS/Modbus message area.

Error

Code

(hex)

Description

Cause

Possible Solution

08

Service not supported The service code is incorrect.

Correct the service code.

09

Invalid attribute value The attribute is incorrect.

Correct the attribute.

0C

Object state conflict

Attempted to change an drive constant
that cannot be changed while the drive is
running.

Stop the drive.

0E

Attribute not settable

Attempted to change a read-only
attribute.

Correct the service code or attribute
setting.

13

Not enough data

The data size is incorrect.

Correct the data size.

14

Attribute not
supported

Attempted to execute a service not
defined for the attribute.

Correct the service code or attribute
setting.

15

Too much data

The data size is incorrect.

Correct the data size.

16

Object does not exist

An unsupported object was specified.

Correct the class or instance setting.

1F

Vendor-specific error

• Attempted to change a drive constant

that cannot be changed while the drive
is running.

• Attempted to change a drive constant

to a value outside the setting range.

• Stop the drive.
• Specify a value within the setting

range.

20

Invalid parameter

Attempted to change to a data value
outside the setting range.

Specify a data value within the setting
range.