10 Wiring

E-17

„

Signal Line Wire Sizes

Following table shows appropriate cables for CN1 and CN2 SERVOPACK connectors.

Wire sizes were selected for three cables per bundle at 40

°

C surrounding air temperature

with the rated current.

Connector Name and

Signal

Item

Specification

Control I/O
Signal
Connector

CN1

Cable

Use twisted-pair or shielded twisted-pair wire.

Applicable wire

AWG24 (0.2 mm

2

), AWG26 (0.12 mm

2

),

AWG28 (0.08 mm

2

), AWG30 (0.05 mm

2

)

Finished cable
dimension

φ16.0 mm (φ0.63 in) MAX.

PG Signal
Connector

CN2

Cable

Use Yaskawa cable, or shielded twisted-pair
wire if Yaskawa cable is not used.

Applicable wire

AWG24 (0.2 mm

2

), AWG26 (0.12 mm

2

),

AWG28 (0.08 mm

2

), AWG30 (0.05 mm

2

)

Use AWG22 (0.33 mm

2

) for the encoder power

supply and AWG26 (0.12 mm

2

) for other sig-

nals. These conditions permit wiring distances
up to 20 m (65.6 ft).

Finished cable
dimension

φ6.8 mm (φ0.27 in) MAX.