13 installation conditions of emc directive, 1 emc installation conditions – Yaskawa Σ-II Series User Manual

Page 26

Advertising
background image

E-24

13 Installation Conditions of EMC Directive

To adapt a combination of a SGM

†

H servomotor and a SGDH/SGDM SERVOPACK to EMC

Directives (EN55011 group 1 class A and EN61000-6-2), the following conditions must be sat-
isfied.

However, because this product is built-in, check that the following conditions are still met after
being installed in the final product.

13.1 EMC Installation Conditions

This section describes the installation conditions that satisfy EMC guidelines for each model
of the SGDH/SGDM SERVOPACK. The conditions required for the standard type (base
mounted) of SERVOPACK are described. Refer to this section for other SERVOPACK
models such as the rack mounted types as well.

This section describes the EMC installation conditions satisfied in test conditions prepared
by Yaskawa. The actual EMC level may differ depending on the actual system’s configura-
tion, wiring, and other conditions.

„

Single-phase 100 V/200 V:

SGDH-A3BE to -02BE (Single-phase 100 VAC, 30 W to 200 W)
SGDH-A3AE to -04AE (Single-phase 200 VAC, 30 W to 400 W)
SGDH-08AE-S (Single-phase 200 VAC, 0.75 kW)
SGDH-15AE-S (Single-phase 200 VAC, 1.5 kW)
SGDM-A3BD, DA to -02BD, DA (Single-phase 100 VAC, 30 W to 200 W)
SGDM-A3AD, DA to -04AD, DA (Single-phase 200 VAC, 30 W to 400 W)

* Connect main power supply to terminals L1-L3 for SGDH-08AE-S and SGDH-15AE-S.

Power Supply
Single-phase
100 VAC or 200 VAC

PE

PE

CN2

CN1

U, V, W

L1, L2 *

L1C, L2C

Ground Plate/Shield Box

Controller

Core

Core

Core

Core

Core

Core

Clamp

Clamp

Clamp

SERVOPACK

Servo-

motor

Encoder

Brake

Noise

Filter

Noise

Filter

Brake Power

Supply

1

2

3

4

Advertising