2 precautions on wiring – Yaskawa Σ-II Series User Manual

Page 23

Advertising
background image

4 WIRING

E-19

4.2 Precautions on Wiring

Take note the following precautions at wiring.

„

Connectable Maximum Number of Stations

Up to 15 slave stations can be connected.

„

Cables

Use the following cables.

For other peripheral devices, refer to

Σ-II series SGM…H/SGDH User’s Manual Design

and Maintenance (SIE-S800-32.2) and

Σ-II series SGDH MECHATROLINK Interface

Module User’s Manual (SIE-C718-4).

„

Total cable length

The total cable length should be 50 m and less.
(Station 1 + Station 2 + ••• Station

≤ 50 m)

„

Terminator

Be sure to install the following terminator on SERVOPACK of terminal station.

Cable

Type

Length (m)

MECHATROLINK Communication Cable
(With connector on both ends)

JEPMC-W6000-A3

0.3

JEPMC-W6000-A5

0.5

JEPMC-W6000-01

1.0

Terminator

Type

MECHATROLINK Communication Terminator

JEPMC-W6020