VS-616/676 Series Option Instruction Manual: Isolated Analog Monitor Card AO-12B2

Page 3

INTRODUCTION

The Isolated Analog Card AO-12B2 mounts to an inverter’s control board via connection to option port
3CN, and is used to output dual analog signals for monitoring the inverter’s status: output frequency, out-
put current, etc. The signal level is jumper selectable for -10 to +10 VDC, 0-20mA, or 4-20mA ranges.

The channels are isolated from the inverter, but not from each other.

The Isolated Analog Monitor Card can be used on any of the following inverters. When inquiring with
the factory, please refer to the specific inverter’s model and code number.

* When used with the G3 and H3 Series Inverters, the AO-12B2 Output Resolution is 11 bits (without

sign, positive polarity output)

Table 1: Description

Name

Code Number

Specifications

Isolated Analog

Monitor Card

AO-12B2

73600-D0110

Output Resolution :

11 bits + SIGN bit
(1/2048)

Isolated Output
Signal Level

:

-10 to +10 volts (5 mA max.)
0 to 20 ma*
4 to 20 ma*

*Note: 600

maximum load

Output Channel

:

Two (2) channels

Isolation

:

2500 VAC

VS-616G3*

VS-616G5

VS-616H3*

VS-676VG3

VS-616VH3