Yaskawa AOI User Manual

Page 19

Advertising
background image

Tag

Description

Digital_Output_1

Digital output one status (M1-M2).

Digital_Output_2

Digital output two status (M3-M4).

Digital_Output_3

Digital output three status (M5-M6).

Digital_Output_Fault

Digital output status of the fault contact (MA-MB-MC).

Digital_Output_Fault_Enable

Bit to enable to the ability to control the fault contact via the network.

Drive_State

Status code of the drive state.

Error_Code

Custom data error code provides additional information on the cause of the custom error bit.

External_Fault

Activating this bit will trigger an EF0 fault in the drive.

Faulted

Drive is in a faulted state.

FaultReset

Activating this bit will reset a fault in the drive (if resettable).

Freq_Cmd

Commanded frequency reference from the network.

Freq_Ref

Frequency reference command that is sent to the drive via the network.

MFI_3

Activating this bit will execute the function programmed for S3.

MFI_4

Activating this bit will execute the function programmed for S4.

MFI_5

Activating this bit will execute the function programmed for S5.

MFI_6

Activating this bit will execute the function programmed for S6.

MFI_7

Activating this bit will execute the function programmed for S7.

MFI_8

Activating this bit will execute the function programmed for S8.

MFO_1

Activating this bit will change the status of multi-function output 1 (M1-M2).

MFO_1_Status

Status of multi-function output 1 (M1-M2).

MFO_2

Activating this bit will change the status of multi-function output 2 (M3-M4).

MFO_2_Status

Status of multi-function output 2 (M3-M4).

MFO_3

Activating this bit will change the status of multi-function output 3 (M5-M6).

MFO_3_Status

Status of multi-function output 3 (M5-M6).

Motor_Rated_Torq

Motor rated torque as defined by the motor. Enter this value to scale the torque command. Enter “100.0”

for a range of 0-100.0%.

Motor_Speed

Motor output speed in Hz.

Net_Control

Activate the bit if start/stop control is desired through the network when b1-02

≠ 3.

Net_Ref

Activate the bit if speed reference control is desired through the network when b1-03

≠ 3.

NetCtrlStatus

Bit is active if start/stop control is through the network.

NetRefStatus

Bit is active if the speed reference is through the network.

Node_Input_Assy

Input assembly data fed into the AOI. Define this data for the AOI to operate.

Node_Output_Assy

Output assembly data fed into the AOI. Define this data for the AOI to operate.

OPE

oPE alarm is present in the drive.

Output_Current

Output current of the drive in amps.

Output_Freq

Output frequency of the drive in Hz.

PG_Count

Encoder feedback counter. The value in quadrature counts of the encoder.

Ready

Drive is in the ready state.

Reset

Fault reset to the drive is active.

RunFwd

Activate the bit to run the drive in the forward direction.

Running

Drive is in run mode.

RunningFwd

Drive is running in the forward direction.

RunningRev

Drive is running in the reverse direction.

RunRev

Activate the bit to run the drive in the reverse direction.

Torq_Ref_Limit

Torque reference or limit that is being sent to the drive. Scaled by Motor_Rated_Torq.

Torque_Actual

Torque value (U1-09) from that drive. Scaled by Motor_Rated_Torq.

UV

Drive is in an under voltage condition.

Warning

Drive is in a warning (alarm) state.

ZSP

Drive is currently at zero speed.

ZSV

Zero servo is activated in the drive.

7 AOI Data Tag Description

YASKAWA TOEP YAICOM 21A Logix Add-On Instruction (AOI) User Guide

19