Yaskawa DS391 User Manual

Page 2

Advertising
background image

DWG. NO. 02Y00025-0297

SHEET NO. 2 OF 7

REL. 01/30/91

( m - d f )

Refer to Sheet 1 for latest change.

Figure 2. Installation of Analog Monitor (AO-08) or (AO-12) in GPD 503 or VCD 703

FRONT
COVER

AO-08 or AO-12
OPTION
BOARD

DIGITAL
OPERATOR

MAIN
CONTROL
BOARD

PLASTIC
STANDOFFS
ON MAIN
BOARD

2CN

3CN

Figure 1. Installation of Analog Monitor (AO-08) or (AO-12) in GPD 515

NOTE: If this option is being installed on a GPD 515 with speed fedback, the speed feedback card needs to
be temporarily un-installed to allow access to the connector 2CN on the Drive’s Control Board and TD1, TD2 &
TD3 on the AO-08 or AO-12 option card.

4. See Figure 1 (GPD 515) or Figure 2 (GPD 503 or VCD 703). Install the option on the Main Control Board,
1PCB, and ensure 3CN is properly connected. Make sure Electrostatic procedure is followed.