Devicenet™ with adr option kit cm012 – Yaskawa DeviceNet with ADR Option Kit CM012 User Manual

Page 4

Advertising
background image

Yaskawa Electric America, Inc. –

www.yaskawa.com

IG.AFD.16, Page 4 of 7

Date: 06/15/2007 Rev: 07-06

DeviceNet™ With ADR Option Kit

CM012

13. Yaskawa Supported Input Instances

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

23 (17h)

Extended

Speed and

Torque

Control

6 Bytes

0

Network

Reference

1

Network

Run

Command

1

Fault Reset

Run Reverse

Run Forward

1

Reserved

2

Speed Reference (Scaled by Parameter o1-03) (U1-01)

3
4

Torque Reference (0.1%) (FVC Mode Only, A1-02 = 3) (U1-09)

5

Note:

1

Not available for G5

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

100 (64h)

Modbus

Message

5 Bytes

0

Function Code (Only Modbus functions register read (03h) and register write (10h) are supported)

1

Register Number

2
3

Data

4

Note:

Refer to output assembly instance 150 (96h) for response.

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

101 (65h)
Standard

Control

8 Bytes

0

Terminal S8

1

Terminal S7

Terminal S6

Terminal S5

Terminal S4

Terminal S3

Terminal S2

Terminal S1

1

Terminal

M5-M6

Terminal

M3-M4

Terminal

M1-M2

Fault Reset

External Fault

2

Speed Reference (Scaled by Parameter o1-03) (U1-01)

3
4

Torque Reference (0.1%) (FVC Mode Only, A1-02 = 3) (U1-09)

5
6

Torque Compensation (0.1%) (FVC Mode Only, A1-02 = 3)

7

Note:

1

G5, F7, and G7 Only

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

105 (69h)

Enhanced

Control/

Modbus

Message

8 Bytes

0

Terminal S8

1

Terminal S7

Terminal S6

Terminal S5

Terminal S4

Terminal S3

Terminal S2

Terminal S1

1

Terminal

M5-M6

Terminal

M3-M4

Terminal

M1-M2

Function Bit 2

2

Function Bit 1

2

Fault Reset

External Fault

2

Speed Reference (Scaled by Parameter o1-03) (U1-01)

3
4

Register Number

5
6

Data

7

Notes:

Refer to output assembly instance 155 (9Bh) for response.

1

G5, F7, and G7 Only

2

Bit 1

Bit 2

Function Description

0

0

No Function

0

1

Read Register

1

0

Write Register

1

1

No Function

Advertising