DeviceNet™ With ADR Option Kit

CM012

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

150 (96h)

Modbus

Message

5 Bytes

0

Function Code

1

1

Register Number

2
3

Data

4

Notes:

Refer to input assembly instance 100 (64h) for command.

1

A Modbus message error is returned if the function code has the MSB (bit 80h) set.

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

151 (97h)
Standard

Control

8 Bytes

0

Fault

Alarm

Drive Ready

Speed Agree

Fault Reset

Running in

Reverse

Zero Speed

Running

Forward

1

Zero Servo

Complete

1

Terminal

M5-M6

Terminal

M3-M4

Terminal

M1-M2

Local Mode

Power Loss

Ride Thru

OPE Error

2

Output Frequency (Scaled by Parameter o1-03) (U1-02)

3
4

Torque Reference (0.1%) (FVC Mode Only, A1-02 = 3) (U1-09)

5
6

Output Current (0.01A or 0.1A, Based on Drive Capacity) (U1-03)

7

Note:

1

Flux Vector Control Mode Only (A1-02 = 3)

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

155 (9Bh)

Enhanced

Control/

Modbus

Message

8 Bytes

0

Fault

Alarm

Drive Ready

Speed Agree

Fault Reset

Running in

Reverse

Zero Speed

Running

Forward

1

Terminal

M5-M6

Terminal

M3-M4

Terminal

M1-M2

Local Mode

Function Bit

2

1

Function Bit

1

1

Undervoltage

OPE Error

2

Output Frequency (Scaled by Parameter o1-03) (U1-02)

3
4

Register Number

5
6

Data

7

Notes:

Refer to input assembly instance 105 (69h) for command.

1

Bit 1

Bit 2

Function Description

0

0

None

0

1

Message Accepted

1

0

Message Error

1

1

Complete

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

157 (9Dh)

Standard

DI/DO

Control

8 Bytes

0

Fault

Alarm

Drive Ready

Speed Agree

Fault Reset

Running in

Reverse

Zero Speed

Running

Forward

1

Zero Servo

Complete

3

Local Mode

Undervoltage

OPE Error

2

Terminal

S10

2

Terminal S9

2

Terminal S8

1

Terminal S7

Terminal S6

Terminal S5

Terminal S4

Terminal S3

3

Terminal

P4-C4

2

Terminal

P3-C3

2

Terminal

M5-M6

Terminal

M3-M4

Terminal

M1-M2

Terminal S12

2

Terminal S11

2

4

Analog Input Terminal A1 Monitor (Terminal 13 on G5) (0.1%) (U1-16)

5
6

Output Frequency (Scaled by Parameter o1-03) (U1-02)

7

Notes:

1

G5, F7, and G7 only

2

G7 Only

3

Flux Vector Control Mode Only (A1-02 = 3)