0 wiring, 0 i/o definitions – Yaskawa G5 Traverse Control User Manual
Page 3
 
Date: 07/01/04, Rev: 04-07
Page 3 of 7
TM.G5SW.005
1.0 Wiring
 
Wire the incoming power, motor, and accessories and control wiring as specified in the GPD515 
Technical Manual TM4515. 
 
 
2.0 I/O Definitions 
 
2.1 New Multi-Function Digital Input Settings 
For Parameters H1-01 through H1-06. 
 
Addition to Table 5-2 Multi-Function Input Terminal Data Settings (Section 5.32)
(2)
Data Function
Description
Availability
80 Disturbed
Waveform
Off
Open = Disturb function enabled 
Closed = Disturb function disabled 
V/f Only
 
 
2.2 New Multi-Function Digital Output Settings 
For Parameters F5-01, F5-02 and H2-01 through H2-03. 
 
Addition to Table 5-3 Multi-Function Output Terminal Data Settings (Section 5.33)
(2)
Data Function
Description
Availability
40
Disturb – Up Status
Closed during the accelerating period 
when Disturb function is enabled 
V/f Only
41
During Disturb
Closed when Disturb Function is 
Active 
V/f Only
2.3 New Multi-Function Analog Input Settings 
For Parameters H3-05 and H3-09. 
None. 
 
2.4 New Multi-Function Analog Output Settings 
For Parameters F4-01, F4-03, H4-01 and H4-04. 
None. 
 
 
 
(2)
GPD 515 Technical Manual TM4515