Yaskawa America, Inc.

Over / under torque

detection level

n098

(OL)
n118

(UL)

160%

10%

L6-02
L6-05

150%

Over / under torque

detection time

n099
(OL)
n119

(UL)

0.1 sec

L6-03
L6-06

0.1 sec

Torque selection in

vector mode

n097

0

-

-

The torque reference value (U1-09) is

always used as comparison value for

torque detection in vector control.

Frequency reference

hold selection (up/down

function)

1n00

0

d4-01

0

V74X

V1000-4X

n100 0

d4-01 0

n100 1

d4-01 1

Speed search

deceleration time

n101

2.0 sec

b3-03

2.0 sec

Speed search

deactivation current

n102

150%

b3-02

A1-02

dep.

Torque compensation

gain

n103

1.0

C4-01

1.00

Torque compensation

time constant

n104

0.3 sec

C4-02

A1-02

dep.

Torque compensation

iron losses

n105

E2-10

o2-04

dep.

Value is different than V74X and

capacity dependent

Motor rated slip

n106

E2-02

o2-04

dep.

Motor line-to-line

resistance

n107

E2-05

o2-04

dep.

Motor leakage

inductance

n108

E2-06

o2-04

dep.

Motor no-load current

n110

E2-03

o2-04

dep.

Slip compensation gain

n111

0.0

C3-01

A1-02

dep.

Slip compensation time

constant

n112

2.0 sec

C3-02

A1-02

dep.

Slip compensation in

regenerative mode

selection

n113

0

C3-04

0

n113 0

C3-04 0

n113 1

C3-04 1

SI-T BUS max.

transmission errors

n114

2

-

-

No ML support.

Stall prevention level

reduction during run in

constant power range

n115

0

L3-23

0

n115 0

L3-23 0

n115 1

L3-23 1

Stall prevention during

run selection

n116

0

L3-05

1

n116 0

L3-05 0

n116 1

L3-05 2

Under torque detection

n117 to

n119

see n096 to n098 (Over torque det)

Multi speed reference 9

n120

0.00 Hz

d1-09

0.00 Hz

Multi speed reference 10

n121

0.00 Hz

d1-10

0.00 Hz

Multi speed reference 11

n122

0.00 Hz

d1-11

0.00 Hz

Drive

Parameter

Function

V74X

V1000-4X

Note

Param.

No.

Initial

Value

Set

Value

Param.

No.

Initial

Value

Set

Value