External Encoder Specifications
Standard voltage levels are TTL (0V to 5V), however, voltage levels up to 12V are
acceptable. If using differential 12V signals, no modification is required. Single
ended 12V signals require a bias voltage applied to the complimentary input, i.e.; use
two 10k resistors, one connected to +12V and the other connected to the LEGEND
signal ground to hold the /A phase and /B phase at 6VDC. Do not use a 24VDC
encoder.
Item
Specifications
Input Format
Quadrature
Pulse and Direction
Maximum Frequency
12 MHz
10
11
34
8
9
Legend-MC I/O
Connector CN5
34
Internal Circuitry
A+phase
A-phase
B-phase
B+phase
External Encoder
+5V or +12V
0V
Shield
Frame
Ground
Digital
Ground
Digital
Ground
2.
4k
2.4
k
4
.7k
6.
8k
4.7
k
6.
8k
VCC
3486
3486
Field Wiring