LEGEND-MC Installation Guide

External Encoder Specifications

Standard voltage levels are TTL (0V to 5V), however, voltage levels up to 12V are
acceptable. If using differential 12V signals, no modification is required. Single
ended 12V signals require a bias voltage applied to the complimentary input, i.e.; use
two 10k resistors, one connected to +12V and the other connected to the LEGEND
signal ground to hold the /A phase and /B phase at 6VDC. Do not use a 24VDC
encoder.

Item

Specifications

Input Format

Quadrature
Pulse and Direction

Maximum Frequency

12 MHz

10

11

34

8

9

Legend-MC I/O

Connector CN5

34

Internal Circuitry

A+phase

A-phase

B-phase

B+phase

External Encoder

+5V or +12V

0V

Shield

Frame

Ground

Digital

Ground

Digital

Ground

2.

4k

2.4

k

4

.7k

6.

8k

4.7

k

6.

8k

VCC

3486

3486

Field Wiring