11 EMC Installation Conditions

37

11 EMC Installation Conditions

This section describes the recommended installation conditions that
satisfy EMC guidelines for each model of the SGDV SERVOPACK. The
conditions required for the standard type (base-mounted) of the
SERVOPACK are described. Refer to this section for other
SERVOPACK models such as the rack-mounted types as well.

This section describes the EMC installation conditions satisfied in test
conditions prepared by Yaskawa. The actual EMC level may differ
depending on the actual system’s configuration, wiring, and other
conditions. However, because this product is built-in, check that the
following conditions are still met after being installed in the user’s
product.

The applicable standards are EN55011/A2 group 1 class A, EN61800-3,
and EN61000-6-2.

Ethernet Communication Cables: Use a category 5 or higher cable with
double, aluminum tape and braided shielding according to the standard
EN50288-2-2.