11 EMC Installation Conditions

41

Three-phase 200 V

SGDV-

AE1A ( = 180, 200, 330) + SGDV-OCC02A

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Safety signal cable

Shield cable

Motor main circuit cable

Shield cable

Encoder cable

Shield cable

Main circuit cable

Shield cable

Ethernet communication cable

Shield cable

U, V, W

L1, L2, L3

L1C, L2C

CN2

CN1

PE

PE

1

3

4

5

CN8

2

One turn

Power supply:

Three-phase 200 VAC

Clamp

Noise

filter

Surge

absorber

Brake Power

Supply

SERVOPACK

Shield box

Two turn

Core

Clamp

Clamp

Clamp

Two turn

Safety unit

General

I/O

Core

Core

Clamp

Encoder

Servomotor

Brake

PC

Controller

6

CN1

1 A/B

MP2600iec

Core

One turn

General I/O

1

CN13

MP2600iec

Core

Clamp

One turn