Appendix 4 constants list – Yaskawa Varispeed-686SS5 CIMR-SSA User Manual

Page 83

Advertising
background image

84

APPENDIX 4 CONSTANTS LIST

The numbers of constants displayed in the digital operator depend on the setting of constant access
level (A1-01). For details, refer to Descirptive Manual for Constants.

Table A−4 Monitor Item List

Constant

No.

Name

Unit

Control Method

(f = Monitor enabled,

× = Monitor disabled)

*1

No.

Open loop vector

Flux vector

U1-01

Speed reference

0.01%

*2

f

f

U1-02

Output frequency

0.01Hz

f

f

U1-03

Output current

0.1A

*3

f

f

U1-04

Control method

[No.]

f

f

U1-05

Motor speed

0.01%

*2

f

f

U1-06

Output voltage reference

0.1V

f

f

U1-07

DC bus voltage

1V

f

f

U1-08

Output power

0.1kW

f

f

U1-09

Torque reference (internal)

0.1%

f

f

U1-10

Input terminal status

[Bit]

f

f

U1-11

Output terminal status

[Bit]

f

f

U1-12

Operation status

[Bit]

f

f

U1-13

Cumulative operation time

1H

f

f

U1-14

Software No. (at FLASH side)

[No.]

f

f

U1-15

Control circuit terminal 13 input voltage

0.1%

f

f

U1-16

Control circuit terminal 14 input current/voltage

0.1%

f

f

U1-17

Control circuit terminal 16 input voltage

0.1%

f

f

U1-18

Motor q-axis current (Iq)

0.1%

f

f

U1-19

Motor d-axis current (Id)

0.1%

f

f

U1-20

Speed reference after soft-start

0.01%

*2

f

f

U1-21

ASR input (speed deviation)

0.01%

f

f

U1-22

ASR output

0.01%

f

f

Monitor

U1-27

q-axis current reference

0.1%

f

f

U1-28

d-axis current reference

0.1%

f

f

U1-29

Voltage limit control output

0.1%

f

f

U1-30

q-axis current control output

0.1%

f

f

U1-31

d-axis current control output

0.1%

f

f

U1-32

Output voltage reference Vq

0.1V

f

f

U1-33

Output voltage reference Vd

0.1V

f

f

U1-36

Output voltage phase

0.1deg

f

f

U1-37

Magnetic-pole position detection value (with PG)

0.1deg

×

f

U1-38

Magnetic-pole position detection estimated value (without PG)

0.1deg

f

×

U1-41

LED check (diagnosis)

f

f

U1-42

Operation status 2

[Bit]

f

f

U1-43

Command 1 from transmission option

[Bit]

f

f

U1-44

Command 2 from transmission option

[Bit]

f

f

U1-45

External torque reference

0.01%

f

f

U1-46

Torque compensation

0.01%

×

f

U1-47

DO-08/H output status

[Bit]

f

f

U1-48

Momentary power loss drop amount

0.01%

f

f

U1-49

Software No. (at CPU side)

[No.]

f

f

U1-50

Speed detection PG counter value

Pulse

×

f

U1-51

Output current phase

0.1deg

f

f

U1-53

PID feedback amount

0.01%

f

f

U1-54

DI-16H input status

[BCD]

f

f

*1

Even if f is indicated, some constants are not displayed depending on access level.

*2

The unit varies depending on the setting of o1-03.

*3

0.01A for models of 7.5 kW or below.