5 Installation Procedure
YASKAWA ELECTRIC TOEP YEAOPT 03 - V1000 Option DI-100 120 Vac Interface Installation Manual
19
Connect the DI-100 to the V1000 drive.
The DI-100 option connects to V1000 drive terminals S1 ~ S7 and SC. External 120 Vac
input devices can then connect to terminals S1 ~ S7 and X2 on the DI-100 option.
shows the control terminal arrangement for the V1000 drive with the DI-100
option.
Figure 9
Figure 10 Terminal Connections
9. Insert the DI-100 Option into the V1000 drive control terminals S1 ~ S7, and SC. Secure
the DI-100 option board by tightening the V1000 terminals. Refer to the V1000 Quick Start
Guide TOEPC71060614, for recommended tightening torque.
V1000 Drive Terminals
DI-100 Option
120 Vac External
Control Wiring