4 modified parameters – Yaskawa 1000 Hz High Frequency Custom User Manual

Page 11

Advertising
background image

4 Modified Parameters

YASKAWA ELECTRIC TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement

11

Table 5 Modified Parameter Setting Ranges

Table 6 Parameters with Modified Defaults

Table 7 New Parameter

Parameter

Name

Setting Range

A1-02

Control Method Selection

0

b4-01

Timer Function On-Delay Time

0.0 ~ 3000.0 s

b4-02

Timer Function Off-Delay Time

0.0 ~ 3000.0 s

b5-20

PID Setpoint Scaling

0, 1, 3

H6-01

Pulse Train Input Terminal RP Function Selection

0, 1, 2

L3-02

Stall Prevention Level during Acceleration

0 ~ 170%

L3-04

Stall Prevention Selection during Deceleration

0 ~ 3

o1-03

Digital Operator Display Selection

0, 1, 3

Parameter

Name

Setting Range

Default

Note

b2-04

DC Injection Braking Time at Stop

0.0 ~ 10.0

0.0 s

Previous default: 0.5

n1-01

Hunting Prevention Selection

0, 1

0 (off)

Previous default: 1 (on)

Parameter

Name

Setting Range

Default

Note

S1-01

On-Delay Compensation Selection

0, 1

1

0: Disabled, 1: Enabled