3 Modifications from Standard Software

3

Modifications from Standard Software

Changed Item

High Frequency Software

Standard Software

Applicable Drive Models

All

All

Maximum Output Frequency

1000 Hz (1167)

<1>

<1> In order to set the frequency reference above 1000 Hz, consult the Yaskawa Application Engineering group at

(800-927-5292) for application review and procedures.

400 Hz

Carrier Frequency

Max: 7 kHz
C6-02: 2, B, C, F

Max: 15 kHz
C6-02: 1 ~ A, F

Drive Current Rating

Fixed at Heavy Duty (HD) ratings

Depends on C6-01

Drive Overload Rating

Fixed at 150%/1 min. (C6-01 fixed)

Depends on C6-01

Control Mode

Fixed at V/f (A1-02 fixed)

V/f, OLV, OLV for PM

DriveWorksEZ (DWEZ)

No

Available

Communication Option Kits

No

Available

Frequency Setting Resolution

Fixed at 0.1 Hz

0.01 Hz (less than 100 Hz)
0.1 Hz (above 10 Hz)

Frequency reference and
output frequency display
units.

<2> <3>

o1-03 parameter (same as b5-20)
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
2: Deleted
3: User Defined (o1-10 and o1-11)

o1-03 parameter (same as b5-20)
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
2: RPM
3: User Defined (o1-10 and o1-11)

<2> MEMOBUS/Modbus frequency reference can be set by 0.1 Hz. For 1000 Hz reference, 10000 (2710Hex) must be

set to 0002Hex MEMOBUS/Modbus register.

<3> Also applies to register data via MEMOBUS/Modbus RTU communication.

Torque Compensation

Enabled only at low speeds.

Refer to New and Modified Software
Functions on page 14

.

Constant throughout the entire
frequency range.

On-Delay Compensation

Enabled only at low speeds. Addition of On-
Delay Compensation Selection parameter S1-
01

Refer to New and Modified Software
Functions on page 14

.

Enabled throughout the entire
frequency range.

Stall Prevention Level During
Acceleration (L3-02)

Maximum setting: 170%

Maximum setting: 150%

Deleted Functions

• All OLV and OLV for PM specific

parameters

• All OLV and OLV for PM specific monitors
• Estimation type Speed Search
• High Slip Braking (HSB)
• Auto-Tuning
• KEB
• Overexcitation Deceleration

Refer to Modified Parameters on page 10

.

-

Advertising