4 modified parameters – Yaskawa 1000 Hz High Frequency Custom User Manual
Page 12

4 Modified Parameters
12
YASKAWA ELECTRIC TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement
Table 8 Parameters with Modified Upper Limits
Parameter
Name
Setting Range
Default
b5-19
PID Setpoint Value
0.0 ~ 1000.0
0.0 Hz
C1-11
Accel/Decel Time Switching Frequency
0.0 ~ 1000.0
0.0 Hz
d1-01
Frequency Reference 1
0.0 ~ 1000.0
0.0 Hz
d1-02
Frequency Reference 2
0.0 ~ 1000.0
0.0 Hz
d1-03
Frequency Reference 3
0.0 ~ 1000.0
0.0 Hz
d1-04
Frequency Reference 4
0.0 ~ 1000.0
0.0 Hz
d1-05
Frequency Reference 5
0.0 ~ 1000.0
0.0 Hz
d1-06
Frequency Reference 6
0.0 ~ 1000.0
0.0 Hz
d1-07
Frequency Reference 7
0.0 ~ 1000.0
0.0 Hz
d1-08
Frequency Reference 8
0.0 ~ 1000.0
0.0 Hz
d1-09
Frequency Reference 9
0.0 ~ 1000.0
0.0 Hz
d1-10
Frequency Reference 10
0.0 ~ 1000.0
0.0 Hz
d1-11
Frequency Reference 11
0.0 ~ 1000.0
0.0 Hz
d1-12
Frequency Reference 12
0.0 ~ 1000.0
0.0 Hz
d1-13
Frequency Reference 13
0.0 ~ 1000.0
0.0 Hz
d1-14
Frequency Reference 14
0.0 ~ 1000.0
0.0 Hz
d1-15
Frequency Reference 15
0.0 ~ 1000.0
0.0 Hz
d1-16
Frequency Reference 16
0.0 ~ 1000.0
0.0 Hz
d1-17
Jog Frequency Reference
0.0 ~ 1000.0
0.0 Hz
d3-01
Jump Frequency 1
0.0 ~ 1000.0
0.0 Hz
d3-02
Jump Frequency 2
0.0 ~ 1000.0
0.0 Hz
d3-03
Jump Frequency 3
0.0 ~ 1000.0
0.0 Hz
E1-04
Maximum Output Frequency
0.0 ~ 1000.0
60.0 Hz
E1-06
Base Frequency
0.0 ~ 1000.0
60.0 Hz
E1-07
Mid Output Frequency
0.0 ~ 1000.0
3.0 Hz
E1-09
Minimum Output Frequency
0.0 ~ 1000.0
1.5 Hz
E1-11
Mid Output Frequency 2
0.0 ~ 1000.0
0.0 Hz
E3-04
Motor 2 Maximum Output Frequency
0.0 ~ 1000.0
60.0 Hz
E3-06
Motor 2 Base Frequency
0.0 ~ 1000.0
60.0 Hz
E3-07
Motor 2 Mid Output Frequency
0.0 ~ 1000.0
3.0 Hz
E3-09
Motor 2 Minimum Output Frequency
0.0 ~ 1000.0
1.5 Hz
E3-11
Motor 2 Mid Output Frequency 2
0.0 ~ 1000.0
0.0 Hz
L4-01
Speed Agreement Detection Level
0.0 ~ 1000.0
0.0 Hz
L4-03
Speed Agreement Detection Level (+/-)
-999.9 ~ 999.9
0.0 Hz