Carrier Frequency
• The carrier frequency upper limit changed from 15.0 kHz to 7.0 kHz and two new patterns
were added. See
.
• The carrier frequency selection parameter (C6-02) has been modified according to
.
•
Refer to Application Notes on page 16
for more information.
Table 12 Carrier Frequency Selection Parameter (C6-02) Settings
Figure 1
Figure 1 Additional Carrier Frequency Patterns
C6-02
Carrier
Frequency
Selection
C6-03
Carrier
Frequency
Upper Limit
C6-04
Carrier
Frequency
Lower Limit
C6-05
Carrier Frequency
Proportional Gain
Note
2
5.0
5.0
0
Same as standard
B
7.0
1.0
12
New setting
C
7.0
1.0
8
New setting
F
2.0
2.0
0
Same as standard
7.0 kHz
42 Hz
Carrier
Frequency
Output
Frequency
292 Hz
Parameter C6-02 = B
1.0 kHz
E1-04
7.0 kHz
62 Hz
Carrier
Frequency
Output
Frequency
437 Hz
Parameter C6-02 = C
1.0 kHz
E1-04