5 new and modified software functions, Carrier frequency, 5new and modified software functions – Yaskawa 1000 Hz High Frequency Custom User Manual

Page 14

Advertising
background image

14

YASKAWA ELECTRIC TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement

5 New and Modified Software Functions

5

New and Modified Software Functions

Carrier Frequency

• The carrier frequency upper limit changed from 15.0 kHz to 7.0 kHz and two new patterns

were added. See

Figure 1

.

• The carrier frequency selection parameter (C6-02) has been modified according to

Table 12

.

Refer to Application Notes on page 16

for more information.

Table 12 Carrier Frequency Selection Parameter (C6-02) Settings

Figure 1

Figure 1 Additional Carrier Frequency Patterns

C6-02

Carrier

Frequency

Selection

C6-03

Carrier

Frequency

Upper Limit

C6-04

Carrier

Frequency

Lower Limit

C6-05

Carrier Frequency

Proportional Gain

Note

2

5.0

5.0

0

Same as standard

B

7.0

1.0

12

New setting

C

7.0

1.0

8

New setting

F

2.0

2.0

0

Same as standard

7.0 kHz

42 Hz

Carrier

Frequency

Output

Frequency

292 Hz

Parameter C6-02 = B

1.0 kHz

E1-04

7.0 kHz

62 Hz

Carrier

Frequency

Output

Frequency

437 Hz

Parameter C6-02 = C

1.0 kHz

E1-04