4 Modified Parameters

12

YASKAWA TM.A1000SW.056 YASKAWA AC Drive - A1000 Custom Software Supplement

Table 9 Deleted Multi-function Digital Inputs (H1 Group) and Digital Outputs (H2 Group)

F1-15

Speed Detection Filter Selection

F1-21,37 PG

1/2

Signal Selection

F1-16~19 zdv

Detection

F1-20,36 PG

Option

Card Disconnect Detection

L2-06~10 KEB

Function

L2-11

DC Bus Voltage Setpoint during KEB (Power KEB)

L2-29~L2-31 KEB

Method

Selection

L3-11,17,19~21,24~26 Overvoltage Suppression Function

L7-06~07 Torque

Limit

Control

N2-01~04 Speed

Feedback

Detection Control (AFR)

N3-01~12

High Slip Braking

N3-14~18 Overexcitation

Deceleration (High Frequency Injection)

N3-13,21,22,23 Overexcitation

Deceleration

N6-01~N6-04 Online

Tuning

N6-05~10 Regenerative

Operation

Control with Motor Feedback (for CLV)

T1-01~T1-11

Auto-Tuning for IM

T3-01~T3-04

Auto-Tuning for PG Motor Encoder

U6-13

Flux Position Detection (sensor)

U6-22

Zero Servo Pulse Movement

U6-25 Feedback

Control

Output

U6-26

Feed Forward Control Output

U6-27

Control Estimation Speed

U6-30 Flux

Reference

U6-41

d-Axis Compensation Voltage

U6-42

q-Axis Compensation Voltage

U6-43

d-Axis Estimated Flux

U6-44

q-Axis Estimated Flux

U6-45

Slip Temperature Compensation

Setting

Function

H0-XX=D

No Speed Control during V/f with PG Control. Closed: Speed feedback disabled
(i.e., normal V/f Control without PG)

H1-XX=16

Motor 2 Selection

H1-XX=65

KEB Ride-Thru 1 (N.C.)

H1-XX=66

KEB Ride-Thru 1 (N.O.)

H1-XX=68

High Slip Braking

H1-XX=71 Speed/Torque

Control

Switch

H1-XX=72 Zero

Servo

H1-XX=78 External

Torque

Reference Polarity Inversion

H1-XX=7A

KEB Ride-Thru 2 (N.C.)

H1-XX=7B

KEB Ride-Thru 2 (N.O.)

H2-XX=1D During

Regeneration

H2-XX=23

Frequency (Speed) Agree 3
Closed: Frequency (Speed) Agree 3 is enabled
(Enabled as defined by L4-02, but disabled during deceleration while the torque limit is active)

H2-XX=31 During

Speed

Limit

H2-XX=32

During Speed Limit in Torque Control

H2-XX=33

Zero Servo Complete

H2-XX=4A During KEB Ride-Thru

H3-XX=13 Torque

Reference/Torque Limit

H6-01=3

V/f Control with Simple PG Feedback

Parameter

Name

Advertising