3 summary of modifications from standard software, Summary of modifications from standard software, 3summary of modifications from standard software – Yaskawa AC Drive - A1000 Option Hz High Frequency Custom User Manual

Page 7

Advertising
background image

3 Summary of Modifications from Standard Software

YASKAWA TM.A1000SW.056 YASKAWA AC Drive - A1000 Custom Software Supplement

7

3

Summary of Modifications from Standard Software

Changed Item

High Frequency Software

Standard Software

Maximum Output
Frequency

1000 Hz

400 Hz

Carrier Frequency

Max: 12.5 kHz

• V/f Control: 1.1 kHz to 12.5 kHz
• Open Loop Vector Control for PM: 1.1 kHz to 10.0 kHz

Max: 15 kHz
C6-02: 1 ~ A, F

Drive Duty Rating

Fixed at Heavy Duty (HD) ratings

Depends on C6-01

Drive Overload
Rating

Fixed at 150 %/1 min. (C6-01 fixed)

Depends on C6-01

Control Mode

0: V/F Control
5: Open Loop Vector Control for PM

0: V/f Control

1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
5: Open Loop Vector Control for PM
6: Advanced Open Loop Vector Control for PM
7: Closed Loop Vector Control for

PM

DriveWorksEZ
(DWEZ)

No

Available

Option Kits

Motor encoder card (PG) not available.
Note: r/min units (8E2H) cannot be used when an option card is
supplying the frequency reference.

Available

Frequency Setting
Resolution

Fixed at 0.1 Hz

0.01 Hz (less than 100 Hz)

Frequency reference
and output frequency
display units.

o1-03 parameter (same as b5-20)
0: 0.1 Hz
1: 0.01 (Max frequency 100 %)
2: Deleted
3: User Defined (o1-10: It is possible to set it within the range of
1..60000)
Note: The setting for o1-04 is fixed at 0 and access is restricted so
that units are always displayed in Hz.

o1-03 parameter (same as b5-20)
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
2: RPM
3: User Defined (o1-10: It is possible to set it within
the range of 1..60000)

o1-04 parameter
0: Hz
1: r/min
Units depend on the setting of A1-02.
Set as a percentage of the maximum
output frequency when using
Advanced OLV for PM.

Torque Compensation

Enabled only at low speeds.
Note: Torque compensation derating function is added.

Refer to Details for New and Modified Software Functions on
page 13

.

Constant throughout the entire frequency range.

On-Delay
Compensation

Enabled only at low speeds. Addition of On-Delay Compensation
Selection parameter S1-01

Refer to Details for New and Modified Software Functions on
page 13

.

Enabled throughout the entire frequency range.

Stall Prevention Level
During Acceleration
(L3-02)

Maximum setting: 170%

Maximum setting: 150%