3 Application Selection

YASKAWA TM.A1000SW.029 Traverse Application A1000 Custom Software Supplement

13

U7-02, Slave Absolute Frequency, (available as an output to the slave by setting parameter H4-01 to 702), has the same
amplitude of 9 Hz (calculated by P1-02

×

Reference Frequency). U7-02 is anti-phase to the master waveform and is

centered around U7-04, the Slave Base Frequency. Since the Slave Base Frequency is 45 Hz, U7-02 varies from
36 to 54 Hz while in Traverse mode. Before entering Traverse mode, the Slave Absolute Frequency will rest at 48 Hz, as
represented by the equation in

Figure 2

.

U7-03, Slave Ripple Frequency, is the same as the U7-02 waveform without the Slave Base Frequency component. Slave
Ripple Frequency U7-03 is a bipolar waveform centered at 0 Hz. The output varies from 21 to 39 Hz during operation.
The Slave Ripple Frequency will rest at 3 Hz before entering Traverse mode as represented by the equation in

Figure 2

.

Figure 2

Figure 2 Master and Slave Output Diagram: Standard Operation

Run Command

Frequency

Reference

Disturb UP Status

multi-function output

During Disturbed

multi-unction output

Speed Agree

P1-04

P1-05

U7-04

Slave Base

Frequency

U7-02

Slave Absolute

Frequency

P1-02 x Freq Ref

P1-02 x Freq Ref x P1-03

0 Hz

U7-03

Slave Ripple

Frequency

P1- 02 x

Freq Ref

0 Hz

P1-02 x Freq Ref x P1-03

2 - P1-03

P1-02 x Freq Ref x P1-03

P1-02 x Freq Ref

P1-02 x Freq Ref

P1-02 x Freq Ref

2 - P1-03

P1-02 x Freq Ref

P1-02 x Freq Ref x P1-03

Advertising