LR Series Receiver Specifications Continued

Parameter

Symbol

Min.

Typ.

Max.

Units

Notes

Max. Time Between

Transitions

10.0

ms

5

Environmental

Operating Temperature

Range

–40

+70

ºC

5

1. The LR can utilize a 4.3 to 5.2VDC supply provided a 330

Ω resistor is placed in series

with V

CC

.

2. Into a 50

Ω load.

3. When operating from a 5V source, it is important to consider that the output will swing

to well less than 5 volts as a result of the required dropping resistor. Please verify that

the minimum voltage will meet the high threshold requirement of the device to which

data is being sent.

4. For BER of 10

–5

at 1,200bps.

5. Characterized, but not tested.

6. Time to valid data output.

Warning:

This product incorporates numerous static-sensitive

components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe
this precaution may result in module damage or failure.

Typical Performance Graphs

Supply

RX Data

RX Data

PDN

Figure 4: Electrical Specifications

Figure 5: Turn-On Time from V

CC

Figure 6: Turn-On Time from PDN

Advertising