Serial connection of multiple basic cradles, Dip switch settings, E-36 – Casio DT-900 User Manual

Page 34: Connections

Advertising
background image

E-36

Using the Basic Cradle

Serial Connection of Multiple Basic Cradles

You can use optional 6-6 pin Modular Cables (DT-788RSC) to
connect up to 16 Basic Cradles in a serial configuration. This
configuration makes it possible to exchange data
between multiple Data Collectors and a personal
computer.

Connections

First connect Basic Cradle RS-
485-1 and then the RS- 485-2 of
the Basic Cradle that you want
to connect to.

DIP Switch Settings

The following table shows the various
settings that are available with the DIP
switches located on the back of the Basic
Cradle.

Important!

• Other settings not shown here are for special-purpose modes, and

should not be used.

1 2 3 4 5 6 7 8

Data Collector - Basic Cradle
Communication Speed

1

2

3

2,400bps

OFF

OFF

OFF

9,600bps

ON

OFF

OFF

19,200bps

OFF

ON

OFF

38,400bps

ON

ON

OFF

57,600bps

OFF

OFF

ON

115,200bps

ON

OFF

ON

Unused

Connection Type

6

7

Host Computer
Connection

ON

ON

(no linking)

Intermediate Unit

OFF

OFF

in Linked Chain

Terminator Unit

ON

OFF

in Linked Chain

RS-232C Control Signal Setting

4

5

RS enabled

ON

ER enabled

ON

RS-232C cable

To host computer

6-6 pin Modular
Cable (DT-788RSC)

Advertising